Back to Journals » International Journal of Chronic Obstructive Pulmonary Disease » Volume 19

Recalibrating Perceptions and Attitudes Toward Nebulizers versus Inhalers for Maintenance Therapy in COPD: Past as Prologue

Authors Dhand R , Hess MW, Yohannes AM 

Received 15 August 2024

Accepted for publication 19 November 2024

Published 28 November 2024 Volume 2024:19 Pages 2571—2586

DOI https://doi.org/10.2147/COPD.S491275

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 3

Editor who approved publication: Dr Richard Russell



Rajiv Dhand,1 Michael W Hess,2 Abebaw Mengistu Yohannes3,4

1Division of Pulmonary and Critical Care Medicine, Department of Medicine, The University of Tennessee Graduate School of Medicine, Knoxville, TN, USA; 2COPD Foundation, Miami, FL, USA; 3Department of Physical Therapy, University of Alabama at Birmingham, Birmingham, AL, USA; 4Division of Pulmonary, Allergy, and Critical Care Medicine, Department of Medicine, University of Alabama at Birmingham, Birmingham, AL, USA

Correspondence: Abebaw Mengistu Yohannes, 372 School of Health Professions, Department of Physical Therapy, University of Alabama at Birmingham, 1720 2nd Avenue South, Birmingham, AL, 35294, USA, Tel +1 (205) 996 1579, Email [email protected]

Abstract: Aerosol therapy administered via handheld inhaler or nebulizer device has long been standard for the treatment of chronic obstructive pulmonary disease (COPD), both for maintenance therapy and for management of acute exacerbations. Of the 2 options for drug delivery, inhaler devices are the most widely used for ambulatory patients with COPD as they are small, portable, and convenient and offer an array of medication options. They are, however, prone to suboptimal inhalation technique and use errors, which decrease the amount of medication delivered, compromise efficacy, and adversely affect clinical outcomes. Nebulizers are less often employed for aerosol delivery than inhalers, particularly in the home environment. Considered bulky and expensive, nebulizers have historically had limited medication options compared with inhalers. Nonetheless, nebulizers may be preferred over inhalers in specific patient populations, such as in patients with poor lung function, lack of hand–breath coordination, or cognitive impairment. Furthermore, technological advances and development of new nebulizer-compatible medications are shifting the benefit equation for nebulizers versus inhalers in a way that merits reconsideration of the role of nebulizers in the maintenance treatment of COPD. Using the available literature, this state-of-the-art review critically evaluates the benefits and limitations of aerosol therapy delivery via inhaler or nebulizer for patients with COPD; describes the factors that may influence the benefit equation, including current advances in nebulizer technology and future developments; and provides insights on implementation of nebulizer therapy in clinical practice.

Keywords: Aerosol therapy, bronchodilator, COPD, exacerbation, inhaler, maintenance

Introduction

Worldwide, there are an estimated 480 million people living with chronic obstructive pulmonary disease (COPD), and this number is anticipated to grow to approximately 600 million by 2050.1 Although historically considered a disease predominantly caused by tobacco exposure, other factors (eg, air pollution, occupational exposures, poorly controlled asthma, infectious disease, cooking fuel smoke, low socioeconomic status, impaired childhood lung growth due to early-life exposures) are now considered to play a significant role in COPD development.2 COPD has a tremendous impact on patients’ lives, reducing quality of life, causing disability, decreasing social interaction, heightening anxiety and depressive symptoms, increasing risk of acute exacerbations and frequent hospitalizations, and contributing to morbidity and premature mortality.3,4

Aerosol therapy—delivered via nebulizer, dry powder inhaler (DPI), pressurized metered-dose inhaler (pMDI), or soft mist inhaler (SMI)—is a mainstay of COPD treatment as well other respiratory conditions such as asthma and cystic fibrosis.5 Aerosol therapies deliver medication directly to the lungs, providing rapid onset of effect and high local drug concentration, thereby increasing efficacy while reducing the risk for side effects associated with increased systemic exposure after oral or intravenous administration.6,7 Handheld inhaler devices have long been used more frequently than nebulizers for aerosol therapy delivery.8–11 Despite the importance and ubiquity of inhaler-based therapies, suboptimal treatment is common because of poor adherence and errors in device use, particularly in patients with COPD who have challenges related to advanced age, cognitive impairment, muscle weakness, and/or comorbidities.12–14 Improper inhaler technique/device use errors are associated with increased exacerbation risk,15–18 worse health status,16,17 overuse of inhaled corticosteroids,19 frequent episodes of emergency care utilization and hospitalizations,20 and higher costs.21 By contrast, optimizing inhaler technique reduces the rates of exacerbations and hospital admissions;22 improves measures of disease control, health status, and quality of life;23,24 and decreases healthcare resource utilization (hospital admissions, hospital length of stay) and costs.22 However, providing patients with instruction on proper inhaler technique does not lead to effective use for many patients, including those with physical or cognitive limitations that preclude execution of optimal inhaler technique.25 Moreover, concern has been raised about inhalers due to propellant restrictions, disposal needs, and a high carbon footprint, particularly for pMDIs.26–28

These challenges, along with advances in device technology and a larger array of medication options available, warrant a reconsideration of nebulizers for aerosol therapy delivery in COPD. As a reflection of the changing landscape, Global Initiative for Chronic Obstructive Lung Disease (GOLD) report iterations have expanded their acceptance of nebulizer therapy over the past 2 decades.29 From 2001 through 2009, GOLD reports did not recommend nebulizer use for maintenance therapy in COPD due their cost and maintenance requirements. In 2010, the GOLD report cautiously included nebulizer therapy within the treatment modalities for COPD, with caveats limiting its use. These caveats were removed in 2017.30 The 2024 GOLD report lists nebulizer formulation options within the main classes of COPD maintenance medications, with certain medications formulated exclusively for nebulizer use.5 Nonetheless, nebulizer use has been in decline while inhaler-based therapy use has increased.10,11 A retrospective analysis of Medicare beneficiaries with COPD from 2008 to 2015 reported decreased nebulizer use, potentially because of increased use of non-nebulized therapies.10

Prescriber and patient perceptions of nebulizer therapy may be influenced by previous guidance and experiences with older devices. To provide a balanced view of nebulizer therapy in the current era and beyond, this review seeks to critically synthesize available literature regarding the benefits and limitations of aerosol therapy delivery via inhaler or nebulizer for patients with COPD, identify patient characteristics and clinical scenarios that influence the decision-making process between inhalers versus nebulizers, describe advances in nebulizer technology and future developments on the horizon, and provide insights for successful implementation of nebulizer-based therapy.

Methods

This critical narrative review was informed by a systematic and structured literature search. A comprehensive search of the MEDLINE database was conducted in May 2024 with terms including those related to the disease state (COPD, emphysema, chronic bronchitis) in combination with treatment modalities (inhaled therapy, aerosol therapy, inhaler, nebulizer) and topics of interest (ease, complexity, technique, impairment, difficulty, acceptance, satisfaction, preference, history, future, emerging, new developments, guidelines, consensus, cost, access, Medicare, Medicaid, coverage, payor, insurance, COVID-19, transmission, education, cleaning, support, caregiver). Results were limited to English-language articles published within the past 10 years. Two hundred thirty-seven abstracts were identified, and 75 articles were found to be responsive to the stated purpose and objectives of the review. Additional relevant publications were identified from reference lists of included articles.

Aerosol Therapy Delivery via Inhaler vs Nebulizer

Inhalers and nebulizers each carry a unique set of advantages and disadvantages. From a class perspective, certain attributes are more favorable for one device or the other (Figure 1). It should be noted, however, that within the broader categories, the different types of inhalers (DPI, pMDI, SMI) and nebulizers (jet, ultrasonic, vibrating mesh) have their own profiles. This section describes the categories in general, with notable specific characteristics highlighted for particular types of devices.

Figure 1 Comparing the attributes of nebulizers and inhalers. Relative ratings represent the opinions of the authors based on literature search results and their knowledge and experience with inhaler and nebulizer devices. Each author independently rated the individual attributes on a 7-point scale that ranged from strongly favors inhalers to strongly favors nebulizers. The resulting score averages and ranges are illustrated on the forest plot. aIndicates that drug delivery is less affected by inhalation technique.

Inhalers

Inhalers have in their favor that they are small (handheld) and self-contained, which makes them convenient and portable.31,32 They are also widely available, encompass most classes of medications used in the maintenance treatment of COPD including combination therapies, may come preloaded with medication, include a dose indicator, have a short treatment time, are low maintenance, and can have a cost advantage over nebulizers.31,32

The key challenge associated with inhalers is suboptimal inhaler technique, which is common among patients with COPD.17,19,22,24,33–55 In the observational, real-world MISMATCH study, which evaluated DPI only or DPI and pMDI use by patients with COPD from 6 countries between October 2022 and May 2021, >90% of the 582 study participants made ≥1 “critical error”, defined as an error that can reduce treatment effectiveness and/or decrease medication delivery to the lung.54,56 Combined data from a multicenter, patient-preference study and an open-label, randomized clinical trial revealed that 91% of the 660 patients did not use correct inhalation technique at baseline despite 85% of patients having received prior inhaler technique instruction.49 Even after repeated use in either the clinical trial or real-world setting, as many as 4 in 10 patients continue to incorrectly use inhaler devices.33,36,49,52,57 Part of the challenge may be that inhaler instruction provided is incomplete or inaccurate because of lack of healthcare professional knowledge regarding proper inhaler use.58 Moreover, “decay” has been observed in inhaler technique, wherein patients who had mastered inhaler technique do not sustain this level of correct use over time.24,56

Several factors have been linked to increased risk for inhaler errors, such as use of >1 inhaler device model concurrently.37,39,47,48 Compared with patients using a single device, the odds of making ≥1 critical error among patients with COPD enrolled in a prospective, cross-sectional, multicenter, observational study were 3 times greater in patients who used 2 devices and almost 9 times higher in patients who used 3 devices.48 Moreover, the use of single inhaler devices has been shown to improve adherence and persistence and may positively affect healthcare outcomes (eg, decrease exacerbation rates, lower the risk of emergency department visits or hospitalizations, shorten hospital length of stay, and reduce healthcare costs) versus use of multiple separate inhalers.59–62 This is an important consideration because use of >1 inhaler device is common in COPD, with studies reporting that 45% to 90% of patients are treated with 2 or more inhalers.38,39,44,55

The inhaler device itself may contribute to the propensity for errors and the type of errors observed.24,34,38,39,41,44–49,55 As noted by the GOLD report, inhaler devices with “increased steps reduces the ease of use and likelihood that patients use the inhaler correctly.”5 It has also been observed that devices with fewer steps to set up the actuation are associated with fewer attempts needed to initially achieve correct technique.63 Certain devices, such as pMDI and to a lesser extent SMIs, require dexterity and coordination of inhalation with device actuation.7,25,64 Despite the lesser need for hand–breath coordination with SMI, they are still prone to errors; a 2020 systemic review found that approximately 60% of patients with COPD using SMI made ≥1 error in device use.64 Hand–breath coordination is not required for DPIs because the patient’s inhalation triggers actuation. However, DPIs are not recommended for patients with low inspiratory flow due to the strength of inhalation needed to overcome the device’s internal resistance and generate the turbulence necessary for optimal aerosol generation.65

Nebulizers

Nebulizers are comparatively easy to use and user friendly.7,66,67 Nebulizers do not require the inspiratory flow, dexterity, coordination, priming, or breath holding of inhalers.7,64,66,67 Patients need only to maintain tidal-volume breathing while the nebulizer provides a continuous flow of aerosolized medication.66 Consequently, nebulizers are less prone to poor inhalation technique, and the consequences thereof, compared with inhalers.25 In a cohort of 300 consecutive patients with bronchial asthma or COPD, a significantly smaller proportion of nebulizer users (70%) made technique errors compared with users of pMDIs (94%), DPIs (82%), or pMDIs with a spacer (78%; p = 0.005).68 The most common errors observed among nebulizer users in this study were no deep breathing throughout the treatment, poor fitting of mask, and incorrect dose of medication used. Another advantage of nebulizers is that they are suitable for delivery of large volume/high medication doses.31,66

A key disadvantage of nebulizers, particularly the older devices, is their size and, for many devices, the requirement for an external power source, which limits their portability.7,25,31,66 Nebulizer therapy takes longer to use than an inhaler, including the time for setup, medication administration (average administration time, 10–15 min for conventional jet nebulizers), and cleanup.25,66 The need for regular cleaning and disinfecting is a drawback for nebulizers. A 2021 systematic review of observational studies that assessed knowledge, attitudes, and practices regarding nebulizer therapy in the home environment reported that cleaning and disinfecting was often inadequate, resulting in pathogen contamination retained on nebulizer components.69 The review also noted that patients failed to service nebulizer components that require routine replacement and that instruction or training on nebulizer use and maintenance is lacking. Nebulizer cleanup and maintenance are recognized by patients with COPD as areas of educational need.70 In a 2023 qualitative study of the transition from hospital to home in 21 patients with COPD receiving nebulizer therapy, no difficulties were noted in nebulizer setup and utilization; however, a need for additional education regarding nebulizer cleanup and maintenance was identified.70 In general, patients did not view portability of their nebulizer as an issue. The perspective about portability may reflect the time frame of the study (2020–2022) and the more frequent use of newer, more portable nebulizers.

With older conventional jet nebulizers, there was variability in drug output and, hence, lung deposition—a problem that is less common with newer, high-efficiency nebulizers.66 The noise associated with operation of conventional jet nebulizers can be an issue for some patients, whereas newer ultrasonic nebulizers and mesh nebulizers run more quietly.67

Cost Considerations

Although nebulizer therapy is viewed as more expensive,25 the cost of inhalers can exceed that of nebulizer therapy in the US.71 A key driver of cost in the inhaler market is the development of branded devices that extend patent exclusivity, a strategy that has been used to great effect to maintain revenue after the active ingredient is off patent.71,72 In contrast, many of the nebulizer solutions are generic.71 Feldman et al71 note that 2020 Medicare Part D spending for a month’s supply of the branded Combivent® Respimat® (albuterol-ipratropium) inhaler averaged $207, whereas spending for generic albuterol and ipratropium as a nebulizer solution was $21. The cost of the nebulizer itself must be factored into the equation, although the device can last for years. These findings are significant because a large proportion of Medicare recipients have COPD (16.5% as of 2018).73 Moreover, cost-related nonadherence, wherein patients intentionally miss doses, take lower than the prescribed dose, or delay filling prescriptions to lower the cost of treatment, affects an estimated 1 in 6 US adults with COPD.74

After implementing a protocol to reduce medication waste associated with unused drug by switching from inhaler-based therapies to nebulizer therapies during hospital stays in patients with COPD, a US-based hospital system reported a $1.56 million (38.5%) reduction in system-wide drug expenditures in year 1 and a $1.65 million (40.6%) reduction in year 2.75 In the year prior to implementation of the nebulizer switch protocol, inhalers accounted for approximately 18% of respiratory drug delivery, yet were responsible for nearly 80% of total drug costs. A limitation of the cost analysis is that the study did not measure the effect of the switching protocol on respiratory therapy labor, which is an important consideration, as the time needed for delivery and documentation is longer for nebulizers than inhalers. Importantly, no negative effects on COPD-related hospital length of stay or 30-day readmissions were observed with the switch to nebulizer therapy.75

From a patient perspective, although some patients report barriers to access related to insurance coverage and acceptance by suppliers, many patients with COPD who participated in a qualitative survey described their COPD medications and nebulizer device as affordable.70 Notably, the majority of patients surveyed (95%) had primary insurance coverage through Medicare, Medicaid, or both, which may have influenced their experience with nebulizer cost. Medicare or dual-enrollment beneficiaries are likely to pay lower coinsurance amounts compared with the general population and may also have low cost-sharing, depending on the type of plan (Original Medicare [OM], OM with a supplemental plan, OM with a Part D plan, or Medicare Advantage).

Patient Experiences and Preferences

Patient satisfaction with or acceptability of inhalers is generally moderate to high, although it does vary among individual devices.33,34,36,57,76–81 Patient satisfaction with their inhaler has been linked to better medication adherence,80,82,83 greater compliance with prescribing instructions and advice,84 higher health-related quality-of-life scores,84 fewer exacerbations,84 and lower error rates. Indeed, an increased risk of errors has been observed among patients with COPD and lower device satisfaction.46

Although the data are limited, patients with COPD report high levels of satisfaction, confidence, and ease of use with nebulizer delivery of aerosol therapy.85–87 In a survey of patients hospitalized with asthma or COPD during the COVID-19 era that compared nebulizer therapy versus a pMDI with a spacer, the majority of patients reported that nebulizer therapy was subjectively more effective, easier to use, and more comfortable.88 The side effect profile was considered by the patients to be similar between the 2 devices, although there was a greater perceived infection risk with nebulizer therapy. Perceived infection risk influenced preference for future treatment, with those patients who believed there to be a greater infection risk with nebulizer therapy less likely to prefer it compared with a pMDI with a spacer.

Experiences with aerosol therapy may differ between patients with COPD compared with those who have asthma because of inherent differences in the patient populations. Patients with COPD are generally older, are more likely to use 2 or more different inhaler devices, receive less training on inhaler technique, take a longer time to learn correct inhaler technique, are more likely to make critical errors, and are less satisfied with inhaler devices than patients with asthma.42,47,63,78,83 With these differences in experience come differences in device preferences between the 2 patient groups.63,78

Factors That Influence the Benefit Equation for Inhalers Vs Nebulizers

Citations in the literature suggest that, when proper inhalation technique is used, aerosol therapy has equivalent efficacy whether delivered via inhaler or nebulizer—a conclusion based on the results of systematic reviews.89–91 The actual benefit derived from aerosol therapy, however, hinges on its appropriate use, which is influenced by a number of factors. It is, therefore, recommended that device choice should weigh elements related to:5,90 the device, including drug and device availability, convenience (size, portability), administration time, cost (for the patient and the healthcare system); the patient, including age, capacity to use the device correctly, number and type of concurrent aerosol therapies, preference, clinician recommendation; and the clinical setting, including the inpatient, outpatient, and home environment.

Among these elements are factors that shift the balance of device attributes in favor of nebulizers (Table 1).5,66,92 Poor health status, in general, has been linked to more inhaler errors in patients with COPD.39 Mental health conditions and negative changes in mood can also influence adherence to aerosol therapy.70 However, the most prevalent patient-related factors that compromise the ability to use inhaler devices correctly and warrant consideration of nebulizer therapy for patients with COPD are advanced age, cognitive impairment, and physical limitations such as muscle weakness, impaired hand dexterity, and insufficient inspiratory flow.

Table 1 Patient Characteristics or Clinical Scenarios That Favor COPD Maintenance Aerosol Therapy Delivered via Nebulizera

Advanced Age

As noted earlier, patients with COPD are on average older than patients with other obstructive respiratory diseases that frequently use aerosol therapy such as patients with asthma or cystic fibrosis.63,93 Advanced age brings with it the increased propensity for comorbidities, including those that impair cognition, impose physical limitations, and reduce dexterity.5 Data have shown that older patients with COPD are more prone to inhaler use errors than younger patients.41,43,45,47,51 In clinical practice, clinicians weigh ease of use and device suitability more heavily in treatment selection for older versus younger patients.79

Cognitive Impairment

A 2017 systematic review that included 14 observational studies with data from 23,116 patients reported pooled prevalences of 25% (95% CI: 23%–42%) for mild cognitive impairment and 32% (95% CI: 18%–38%) for any cognitive impairment in patients with COPD.94 The likelihood of cognitive deficits is enhanced among those with poor lung function, who require supplemental oxygen, or who are experiencing or recovering from an acute exacerbation of COPD.95 In a small cohort of patients with a recent hospitalization or emergency department visit for a COPD exacerbation, 62% met the criteria for mild cognitive impairment or dementia.95 Notably, patients with mild cognitive impairment or dementia were significantly more likely to demonstrate incorrect pMDI inhaler technique than patients with normal cognitive function even after adjustment for potential confounders (odds ratio, 18.94 [95% CI: 2.65–401.99]). These data align with overall findings that lower cognitive score/cognitive impairment impedes the ability to use inhaler devices correctly.24,41,96 The presence of cognitive impairment also predicts decay of inhaler technique (ie, an increase in errors) over time.24

Although a nebulizer may be beneficial for successful delivery of aerosol therapy in patients with cognitive impairment, it is important to note that not all patients will be able to independently set up a nebulizer device and would, therefore, require family or caregiver assistance.

Muscle Weakness and Hand Dexterity

The presence of comorbid conditions such as severe pain or muscle weakness due to neurologic/neuromuscular conditions (eg, Parkinsonism, stroke) or musculoskeletal conditions (eg, arthritis) that affect hand dexterity can compromise a patient’s ability to properly use an inhaler device.7,66 A small observational study reported that measures of hand grip strength and endurance were, respectively, 15% and 28% lower in patients with stable COPD than in volunteers without respiratory problems.97 Moreover, a positive correlation has been observed between cognitive scores and hand grip strength and dexterity in patients with COPD.98 Low handgrip strength has also been shown to predict 30-day readmissions after an acute exacerbation of COPD.99 Decreased hand strength has been identified as a predictor of incorrect pMDI use in older patients.99,100 With DPI, the presence of hand tremors or shaking could lead to partial loss of the administered dose.7

As with cognitive impairment, the presence of muscle weakness or hand dexterity challenges may favor nebulizer use; however, individual patients may require family or caregiver assistance to set up and maintain the device.

Insufficient Peak Inspiratory Flow Rate

Peak inspiratory flow rate (PIFR) may be low in patients with COPD because of an acute exacerbation, lung hyperinflation, hypoxemia, and/or muscle wasting. The inspiration flow rate required for effective medication delivery varies among inhalers, from approximately 20 L/min for pMDIs to 30 L/min for high-resistance DPIs and >100 L/min for low-resistance DPIs.101,102 Due to their mechanism of action, SMI delivery is generally independent of inspiratory flow rate. In a small observational study, 40% of patients with stable COPD had insufficient PIFR to meet the specifications of their inhaler device.103 Among patients hospitalized for an acute exacerbation of COPD, a separate study reported that 52% of patients had suboptimal PIFR (≤60 L/min).104 Of patients aged >65 years, the proportion with suboptimal PIFR increased to 60%. For patients with low PIFR, discharge with aerosol therapy via a nebulizer versus a DPI was associated with significantly lower rates of all-cause (30-day: 0% vs 50%; 90-day: 17% vs 70%) and COPD-related (30-day: 0% vs 50%; 90-day: 17% vs 70%) readmissions, respectively (p < 0.05).

A multicenter, randomized, double-blind, active-comparator clinical trial compared bronchodilation with the long-acting muscarinic antagonist (LAMA) revefenacin delivered via nebulizer with that of the LAMA tiotropium delivered via DPI for patients with moderate to very severe COPD and PIFR <60 L/min against resistance of the Diskus® inhaler.105 For the overall study population, changes in trough forced expiratory volume in 1 second (FEV1) and trough forced vital capacity (FVC) were not significantly different between the 2 LAMA delivery mechanisms; however, in patients with baseline FEV1 <50% predicted, treatment with nebulized revefenacin resulted in a greater change in trough FEV1 and trough FVC than treatment with DPI tiotropium.105

Nebulizer Therapy and Respiratory Infection Transmission

In 2020, the COVID-19 pandemic brought to the forefront concerns about infectious respiratory disease transmission during aerosol-generating procedures.106–112 Clinicians and professional organization opinions differed with regard to whether drug administration via nebulizer qualifies as an aerosol-generating procedure and if it was safe in light of the ongoing pandemic.112 Recommendations to reduce virus transmission with nebulized therapy during the COVID-19 pandemic have been interpreted by some to mean that nebulizers are not recommended for the management of COPD.113 Consequently, many clinicians switched their patients from nebulizer therapies to inhalers112 and nebulizer use during hospitalization for acute exacerbations of COPD decreased.111

In 2024, the COPD Foundation Nebulizer Consortium (CNC) published guidance on mitigating the risk of transmitting respiratory infections during nebulization.112 Based on the available published literature, the CNC report concluded that the current evidence is insufficient to classify nebulizer therapy as an aerosol-generating procedure; data are inconclusive regarding a direct relationship between nebulizer use and infection transmission; and “nebulizer use should not be discouraged when clinically indicated.”

The CNC report further provides guidance on strategies for mitigating infection transmission risk and increasing the safety of aerosol drug delivery in both the healthcare and home environments.112 The home environment recommendations are consistent with the 2024 GOLD report, which suggests that spread of infection can be limited by implementing precautions such as avoiding nebulizer use in the presence of others and using the nebulizer near an open window or in a space with increased air circulation.5 The CNC recommendation for continued use of nebulizer therapy when clinically indicated is also consistent with the 2024 consensus panel on the utilization of nebulized budesonide for managing asthma and COPD in both stable and exacerbation stages in Thailand, which recommends continuing nebulization in patients with COPD for whom it may be beneficial as long as appropriate COVID-19 transmission safety measures are applied.114

Taken together, the current recommendations indicate that nebulizer use remains a viable option for aerosol therapy delivery in the inpatient, outpatient, or home settings as long as appropriate safety precautions are utilized.

Nebulizer Options and Advances

The predominant categories of nebulizers used in treatment of COPD include jet nebulizers, ultrasonic nebulizers, and vibrating mesh nebulizers (Table 2).66,67,112,115 Among these, jet nebulizers are the least expensive and most commonly used.116,117 Jet nebulizers use compressed air or oxygen to force air through a constricted outlet at high velocity, thereby generating a vacuum that draws liquid up from the reservoir, which collides with the air “jet” in the chamber resulting in aerosol creation.115 Jet nebulizers can produce aerosol continuously or preferentially during inspiration (ie, breath-enhanced and breath-actuated jet nebulizers). The latter design reduces medication waste and environmental contamination due to the release of fugitive aerosols into the environment during exhalation. Waste with jet nebulizers is also generated by retention of medication in the nebulizer and tubing, resulting in reduced lung deposition.117 With breath-enhanced jet nebulizers, the release of medication is greater during inhalation than exhalation.115 Breath-actuated jet nebulizers have the ability to sense a patient’s inspiratory flow and limit aerosol release to inhalation.

Table 2 Attributes by Type of Nebulizer

Ultrasonic nebulizers generate aerosols by producing high-frequency vibrations that create oscillation on the surface of the liquid.115 Compared with jet nebulizers, the aerosol particles produced by ultrasonic nebulizers are more consistent in size, the output rate is higher, and the administration time is lower. Ultrasonic nebulizers are less widely used, however, because of their cost, size, propensity for mechanical issues, and inefficiency when used for nebulizing suspensions and other viscous solutions.

Vibrating mesh nebulizers produce aerosol by passing liquid through holes in a vibrating mesh.115 Vibrating mesh nebulizers are smaller and quieter than jet nebulizers and are more portable and have a shorter treatment time than either jet or ultrasonic nebulizers.66,67,115 A 2024 systematic review and meta-analysis that included 10 studies comparing vibrating mesh nebulizers with jet nebulizers in a total of 314 patients with COPD reported that the former is associated with greater dose of drug delivered compared with the latter.117 The analysis also found that more aerosol was emitted with vibrating mesh nebulizers than with jet nebulizers. No differences were observed with respect to lung function or lung capacity. In a real-world assessment, patients with COPD rated the eFlow® vibrating mesh nebulizer high in portability, ease of cleaning, size, weight, administration time, and relative noise.86 Among patients who had previously used a nebulizer, 80% reported an increase in satisfaction with eFlow versus their previous nebulizer. Drawbacks of vibrating mesh nebulizers include high cost, the potential for viscous solutions and suspensions to clog the mesh, and difficulty cleaning.117 Vibrating mesh nebulizers typically require cleaning after every use. However, assessment of a disposable vibrating mesh nebulizer (Aerogen® Solo) found that it could be used 3 times per day for 28 days without rinsing or washing with no degradation in performance.118 The aperture plates became partially occluded within the first week of use, but this change did not appear to harm device performance.

Overall, nebulizers have become quieter, more portable, and more efficient, thereby increasing the feasibility for nebulizer use to move from the hospital/clinic setting to the home environment.

Medications Compatible with Nebulizer Delivery

Development has also advanced on the medication side of nebulizer therapy, with the main classes of COPD maintenance aerosol therapies now available in nebulizer formulations, including short-acting beta-agonists (SABAs), long-acting beta-agonists (LABAs), short-acting muscarinic antagonists (SAMAs), and LAMAs, as well as combinations of SABA and SAMA (Table 3).5,7,119,120 The nebulizer formulation of the LAMA revefenacin is a comparatively newer addition to the aerosol therapy armamentarium.7,121 The corticosteroid budesonide is available as a nebulizer formulation and is recommended as an alternative to systemic corticosteroids for select patients with an acute exacerbation of COPD.5,114 A 2024 expert consensus panel from Thailand also recommended nebulized budesonide as an alternative to inhaled corticosteroids in stable patients with COPD, particularly those with frequent exacerbations or who are unable to correctly use a DPI or pMDI.114 However, as budesonide is formulated as a suspension, it cannot be used in an ultrasonic nebulizer.122

Table 3 Nebulized Therapies for Maintenance Treatment of COPD

There are currently limited data for use of nebulized antibiotics in patients with COPD.119 An advantage of the aerosol route for antibiotic administration is that it limits systemic exposure versus oral antibiotics.119 There is preliminary evidence supporting use of nebulized antibiotics for the prevention of acute exacerbations in patients colonized with Pseudomonas aeruginosa, but further investigation is needed to determine the utility of nebulized antibiotics in COPD.7,119,120

The next iteration of nebulizer therapies is likely to involve additional fixed-dose combination agents such as LAMA/LABA,7 as well as development of new medications such as the dual phosphodiesterase 3/phosphodiesterase 4 (PDE3/PDE4) inhibitor, ensifentrine.7,106 Ensifentrine (previously called RPL554) is described by Cazzola et al123 as a “‘first-in-class’ drug having bifunctional bronchodilator and anti-inflammatory activity in a single molecule” that acts on 3 mechanisms involved in the pathogenesis of COPD: bronchoconstriction, inflammation, and dysfunctional mucociliary clearance. Ensifentrine has been evaluated in clinical trials as an adjunct to LAMAs or LABAs,124 but there are limited data on use when added to LAMA/LABA combination therapy or triple therapy.123 Notably, ensifentrine does not have the tolerability issues that have limited the utilization of other PDE inhibitors.123,125,126 Ensifentrine (Ohtuvayre™, Verona Pharma) was approved by the US Food and Drug Administration for the maintenance treatment of COPD in adult patients in June 2024.

Clinical Pearls for Nebulizer Use in Clinical Practice

Implementing effective aerosol therapy is a multistep process that involves communication and shared decision-making between the patient and the clinician. The first step in the process is choosing a suitable medication and device for administration of that medication. There is no device that is universally appropriate for all patients; it is imperative to ensure that the device aligns with the patient’s needs, abilities, preferences, and access.5,112 As data have shown, in clinical practice a prescribed inhaler regimen often does not align with patient needs due to divergence from guideline recommendations and/or lack of insurance coverage.127

Tools are available to assist in determining a patient’s suitability for a particular inhaler device. In-Check DIAL™ (Clement Clarke), which measures a patient’s inspiratory effort, is a multipatient device with a disposable, single-use mouthpiece.128 The device’s resistance can be adjusted to approximate different types of inhalers. In-Check DIAL can also be used for instructional/training purposes. The Aerosol Inhalation Monitor (Vitalograph® AIM™) is a single-use disposable inhaler simulator that assesses multiple aspects of a patient’s inhaler technique, including canister activation, inspiratory flow rate, breath hold time, and inhalation time.129 Like In-Check DIAL, it can be used for initial assessment and training. Both devices are suitable for use in clinic or pharmacy settings. Instructional videos demonstrating how to use these devices as well as many other inhaler and nebulizer devices are freely available online, produced by the device manufacturers or by professional organizations such as the COPD Foundation (COPDFoundation.org).

Although there is no comparable assessment tool for determining nebulizer suitability, the characteristics shown in Table 1 are a helpful guide for patient types and clinical scenarios that favor COPD maintenance aerosol therapy delivered via nebulizer rather than inhaler.

Once the choice of aerosol therapy has been determined, patient education and training are key to ensuring appropriate device use. Based on the available literature for inhaler devices, it is known that reading the patient information leaflet is insufficient for many patients to master inhaler technique; face-to-face instruction by a trained professional is recommended.34 Moreover, training is associated with higher patient satisfaction with an inhaler device,83 which in turn is linked to better adherence and patient outcomes.112 For nebulizers, training in general and cleaning and maintenance in particular have been identified by patients as areas of educational need.70,87,130 In a survey of 254 patients with COPD, only 47% recalled having been trained on how to use their inhaler or nebulizer device and few patients remembered discussing cleaning of the device.87 In a separate study, 31 of 50 patients with COPD surveyed did not feel adequately informed about nebulizer use, and only 7 recalled being taught how to use and clean the device.130 These findings are consistent with a survey of 205 pulmonologists in which only 9% indicated that they discuss device cleaning and storage at a patient’s first visit.131 This lack of education and training could explain why a large proportion of patients with COPD fail to wash nebulizer components after use and to disinfect the device.130 Patients should also be made aware of any nebulizer maintenance needs, such as periodic replacement of the air filter for jet nebulizer compressors. If a patient depends on a caregiver to assist with nebulizer use, the caregiver should be included in the education and training.132

As described in this review, aerosol therapy is prone to suboptimal technique and use errors, which can adversely affect treatment efficacy and outcomes. Incorrect use of nebulizers by patients in the home environment can range from errors in assembling and operating the device through cleaning, drying, and maintaining the nebulizer.130 It is, therefore, important to assess that patients are using their devices correctly at the outset and periodically thereafter.5

It is important to note that although this review sought to present an unbiased assessment of both handheld inhalers and nebulizers for the maintenance treatment of COPD, there are limitations that influence the ability to draw conclusions from the data. For example, the breadth and depth of clinical research, particularly in regard to technique errors, patient satisfaction, and ease of use, is greater for inhalers than for nebulizers. Moreover, criteria used to define technique errors, critical errors, and patient satisfaction varied among studies, making it difficult to compare findings. The studies themselves were heterogeneous with regard to patient populations (eg, disease severity, prior aerosol therapy experience) and the training provided to patients. There was also often a lack of detailed information on the relationship between device error rates and clinical outcomes. Last, as noted when describing propensity to errors, not all devices within a category have the same attributes and should ideally be considered on an individual basis. Greater insight into matching the right patient to the right device could be gained through prospective, randomized controlled trials and additional research evaluating nebulizer devices within different subsets of patients with COPD.

Conclusions

Nebulizers of the modern era represent a significant advance over their predecessors, with newer versions that provide more consistent and efficient medication delivery and have greater portability. With these features and a wider range of medication options, nebulizers warrant consideration as an alternative to handheld inhalers. The most important consideration for choosing an aerosol therapy delivery method is that the patient is able to access and use it correctly. For many patients with COPD, including those with cognitive impairment or physical limitations that preclude optimal inhaler use, the benefit equation favors nebulizers. With appropriate education and training, nebulizer therapy is a viable option for the maintenance treatment of COPD.

Abbreviations

CNC, COPD Foundation Nebulizer Consortium; COPD, chronic obstructive pulmonary disease; DPI, dry powder inhaler; FEV1, forced expiratory volume in 1 second; FVC, forced vital capacity; GOLD, Global Initiative for Chronic Obstructive Lung Disease; LABA, long-acting beta-agonist; LAMA, long-acting muscarinic antagonist; OM, Original Medicare; PDE3, phosphodiesterase 3; PDE4, phosphodiesterase 4; PIFR, peak inspiratory flow rate; pMDI, pressurized metered-dose inhaler; SABA, short-acting beta-agonist; SAMA, short-acting muscarinic antagonist; SMI, soft mist inhaler.

Acknowledgments

Medical writing support for the development of this article was provided by Crystal Murcia, PhD, CMPP, MWC, and Sara N. Fischer, PhD, CMPP, from Citrus Scientific, a Citrus Health Group, Inc. company (Chicago, IL), which was funded by Verona Pharma plc (Raleigh, NC) in accordance with Good Publication Practice (GPP 2022) guidelines.

Author Contributions

All authors were involved in the manuscript’s conception and execution; participated in the analysis and interpretation of the data; critically reviewed and revised manuscript drafts; agreed on the journal to which the manuscript was submitted; and provided approval of manuscript versions throughout the development process. All authors agree to be accountable for the contents of the article.

Disclosure

RD has received research funding from Theravance/Mylan and Viatris and medications for research from Mylan and Theravance; has served as a consultant for Verona; receives royalties from UpToDate and Taylor and Francis. MWH reports that his employer, the COPD Foundation, receives funding from various pharma sources including Verona, Theravance, Viatris, GSK, and AstraZeneca. AMY has received travel support from Theravance. The authors report no other conflicts of interest in this work.

References

1. Boers E, Barrett M, Su JG, et al. Global burden of chronic obstructive pulmonary disease through 2050. JAMA Network Open. 2023;6(12):e2346598. doi:10.1001/jamanetworkopen.2023.46598

2. Yang IA, Jenkins CR, Salvi SS. Chronic obstructive pulmonary disease in never-smokers: risk factors, pathogenesis, and implications for prevention and treatment. Lancet Respir Med. 2022;10(5):497–511. doi:10.1016/S2213-2600(21)00506-3

3. Miravitlles M, Ribera A. Understanding the impact of symptoms on the burden of COPD. Respir Res. 2017;18(1):67. doi:10.1186/s12931-017-0548-3

4. Safiri S, Carson-Chahhoud K, Noori M, et al. Burden of chronic obstructive pulmonary disease and its attributable risk factors in 204 countries and territories, 1990-2019: results from the Global Burden of Disease Study 2019. BMJ. 2022;378:e069679. doi:10.1136/bmj-2021-069679

5. Global Initiative for Chronic Obstructive Lung Disease (GOLD). Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease: 2024 report. Availabe from: https://goldcopd.org/2023-gold-report-2/. Accessed March 27, 2024.

6. Borghardt JM, Kloft C, Sharma A. Inhaled therapy in respiratory disease: the complex interplay of pulmonary kinetic processes. Can Respir J. 2018;2018:2732017. doi:10.1155/2018/2732017

7. Barjaktarevic IZ, Milstone AP. Nebulized therapies in COPD: past, present, and the future. Int J Chron Obstruct Pulmon Dis. 2020;15:1665–1677. doi:10.2147/COPD.S252435

8. Nishi SPE, Maslonka M, Zhang W, Kuo YF, Sharma G. Pattern and adherence to maintenance medication use in medicare beneficiaries with chronic obstructive pulmonary disease: 2008-2013. Chronic Obstr Pulm Dis. 2018;5(1):16–26. doi:10.15326/jcopdf.5.1.2017.0153

9. Chokhani R, Muttalif AR, Gunasekera K, Mukhopadhyay A, Gaur V, Gogtay J. Understanding practice patterns of COPD: a survey of physicians in Nepal, Sri Lanka and Malaysia. Pulm Ther. 2021;7(1):251–265. doi:10.1007/s41030-021-00153-w

10. Singh M, Duarte AG, Hsu ES, Kuo YF, Sharma G. Trends and factors associated with nebulized therapy prescription in older adults with chronic obstructive pulmonary disease from 2008 to 2015. J Aerosol Med Pulm Drug Deliv. 2020;33(3):161–169. doi:10.1089/jamp.2019.1582

11. McCabe H, Godman B, Kurdi A, et al. Prescribing trends of inhaler treatments for asthma and chronic obstructive pulmonary disease within a resource-constrained environment in the Scottish national health service: findings and implications. Expert Rev Respir Med. 2019;13(7):679–689. doi:10.1080/17476348.2019.1624528

12. Sanchis J, Gich I, Pedersen S, on behalf of the Aerosol Drug Management Improvement Team (ADMIT). Systematic review of errors in inhaler use: has patient technique improved over time? Chest. 2016;150(2):394–406. doi:10.1016/j.chest.2016.03.041

13. Chrystyn H, van der Palen J, Sharma R, et al. Device errors in asthma and COPD: systematic literature review and meta-analysis. NPJ Prim Care Respir Med. 2017;27(1):22. doi:10.1038/s41533-017-0016-z

14. Jansen EM, van de Hei SJ, Dierick BJH, et al. Global burden of medication non-adherence in chronic obstructive pulmonary disease (COPD) and asthma: a narrative review of the clinical and economic case for smart inhalers. J Thorac Dis. 2021;13(6):3846–3864. doi:10.21037/jtd-20-2360

15. Molimard M, Raherison C, Lignot S, et al. Chronic obstructive pulmonary disease exacerbation and inhaler device handling: real-life assessment of 2935 patients. Eur Respir J. 2017;49(2):1601794. doi:10.1183/13993003.01794-2016

16. Gregoriano C, Dieterle T, Breitenstein AL, et al. Use and inhalation technique of inhaled medication in patients with asthma and COPD: data from a randomized controlled trial. Respir Res. 2018;19(1):237. doi:10.1186/s12931-018-0936-3

17. Kocks J, Bosnic-Anticevich S, van Cooten J, et al. Identifying critical inhalation technique errors in dry powder inhaler use in patients with COPD based on the association with health status and exacerbations: findings from the multi-country cross-sectional observational PIFotal study. BMC Pulm Med. 2023;23(1):302. doi:10.1186/s12890-023-02566-6

18. Halpin DMG, Mahler DA. Systematic review of the effects of patient errors using inhaled delivery systems on clinical outcomes in COPD. BMJ Open Respir Res. 2024;11(1). doi:10.1136/bmjresp-2023-002211

19. Griffith MF, Feemster LC, Donovan LM, et al. Poor metered-dose inhaler technique is associated with overuse of inhaled corticosteroids in chronic obstructive pulmonary disease. Ann Am Thorac Soc. 2019;16(6):765–768. doi:10.1513/AnnalsATS.201812-889RL

20. Roggeri A, Micheletto C, Roggeri DP. Inhalation errors due to device switch in patients with chronic obstructive pulmonary disease and asthma: critical health and economic issues. Int J Chron Obstruct Pulmon Dis. 2016;11:597–602. doi:10.2147/COPD.S103335

21. Lewis A, Torvinen S, Dekhuijzen PN, et al. The economic burden of asthma and chronic obstructive pulmonary disease and the impact of poor inhalation technique with commonly prescribed dry powder inhalers in three European countries. BMC Health Serv Res. 2016;16:251. doi:10.1186/s12913-016-1482-7

22. Capstick TG, Azeez NF, Deakin G, Goddard A, Goddard D, Clifton IJ. Ward based inhaler technique service reduces exacerbations of asthma and COPD. Respir Med. 2021;187:106583. doi:10.1016/j.rmed.2021.106583

23. Dudvarski Ilic A, Zugic V, Zvezdin B, et al. Influence of inhaler technique on asthma and COPD control: a multicenter experience. Int J Chron Obstruct Pulmon Dis. 2016;11:2509–2517. doi:10.2147/COPD.S114576

24. Iamthanaporn C, Wisitsartkul A, Chuaychoo B. Cognitive impairment according to Montreal Cognitive Assessment independently predicts the ability of chronic obstructive pulmonary disease patients to maintain proper inhaler technique. BMC Pulm Med. 2023;23(1):144. doi:10.1186/s12890-023-02448-x

25. Terry PD, Dhand R. Maintenance therapy with nebulizers in patients with stable COPD: need for reevaluation. Pulm Ther. 2020;6(2):177–192. doi:10.1007/s41030-020-00120-x

26. Janson C, Henderson R, Lofdahl M, Hedberg M, Sharma R, Wilkinson AJK. Carbon footprint impact of the choice of inhalers for asthma and COPD. Thorax. 2020;75(1):82–84. doi:10.1136/thoraxjnl-2019-213744

27. Plusa T, Badowska-Kozakiewicz AM. Carbon footprint of inhalers in COPD therapy in 2018 and 2019 in Poland in response to the Kigali amendment. Pol Merkur Lekarski. 2020;48(288):391–393.

28. Caron C, Sajwani S, Bateman K, et al. Environmentally sustainable opportunities for health systems: metered-dose inhaler prescribing, dispensing, usage, and waste at The Ottawa Hospital. Lancet Planet Health. 2024;8(1):S5. doi:10.1016/S2542-5196(24)00070-6

29. Terry PD, Dhand R. Inhalation therapy for stable COPD: 20 years of GOLD reports. Adv Ther. 2020;37(5):1812–1828. doi:10.1007/s12325-020-01289-y

30. Global Initiative for Chronic Obstructive Lung Disease (GOLD). Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease: 2017 report. Availabe from: https://goldcopd.org/wp-content/uploads/2017/02/wms-GOLD-2017-FINAL.pdf. Accessed June 20, 2024.

31. Pleasants RA, Hess DR. Aerosol delivery devices for obstructive lung diseases. Respir Care. 2018;63(6):708–733. doi:10.4187/respcare.06290

32. Melani AS. Inhaler technique in asthma and COPD: challenges and unmet knowledge that can contribute to suboptimal use in real life. Expert Rev Clin Pharm. 2021;14(8):991–1003. doi:10.1080/17512433.2021.1929922

33. Pascual S, Feimer J, De Soyza A, et al. Preference, satisfaction and critical errors with Genuair and Breezhaler inhalers in patients with COPD: a randomised, cross-over, multicentre study. NPJ Prim Care Respir Med. 2015;25:15018. doi:10.1038/npjpcrm.2015.18

34. van der Palen J, Thomas M, Chrystyn H, et al. A randomised open-label cross-over study of inhaler errors, preference and time to achieve correct inhaler use in patients with COPD or asthma: comparison of ELLIPTA with other inhaler devices. NPJ Prim Care Respir Med. 2016;26:16079. doi:10.1038/npjpcrm.2016.79

35. Mahon J, Fitzgerald A, Glanville J, et al. Misuse and/or treatment delivery failure of inhalers among patients with asthma or COPD: a review and recommendations for the conduct of future research. Respir Med. 2017;129:98–116. doi:10.1016/j.rmed.2017.05.004

36. Oliveira MVC, Pizzichini E, da Costa CH, et al. Evaluation of the preference, satisfaction and correct use of Breezhaler((R)) and Respimat((R)) inhalers in patients with chronic obstructive pulmonary disease - INHALATOR study. Respir Med. 2018;144:61–67. doi:10.1016/j.rmed.2018.10.006

37. Lindh A, Theander K, Arne M, et al. Errors in inhaler use related to devices and to inhalation technique among patients with chronic obstructive pulmonary disease in primary health care. Nurs Open. 2019;6(4):1519–1527. doi:10.1002/nop2.357

38. Vytrisalova M, Hendrychova T, Touskova T, et al. Breathing out completely before inhalation: the most problematic step in application technique in patients with non-mild chronic obstructive pulmonary disease. Front Pharmacol. 2019;10:241. doi:10.3389/fphar.2019.00241

39. Amini S, Ghasemi A, Solduzian M, et al. Is inhaler technique associated with quality of life in patients with chronic obstructive pulmonary disease? Curr Ther Res Clin Exp. 2020;93:100608. doi:10.1016/j.curtheres.2020.100608

40. Elander A, Gustafsson M. Inhaler technique and self-reported adherence to medications among hospitalised people with asthma and COPD. Drugs Real World Outc. 2020;7(4):317–323. doi:10.1007/s40801-020-00210-x

41. Maricoto T, Santos D, Carvalho C, Teles I, Correia-de-Sousa J, Taborda-Barata L. Assessment of poor inhaler technique in older patients with asthma or COPD: a predictive tool for clinical risk and inhaler performance. Drugs Aging. 2020;37(8):605–616. doi:10.1007/s40266-020-00779-6

42. Perumal R, Leite M, van Zyl-Smit RN. The relationship between clinical trial participation and inhaler technique errors in asthma and COPD patients. Int J Chron Obstruct Pulmon Dis. 2020;15:1217–1224. doi:10.2147/COPD.S249620

43. Ramadan WH, Sarkis A, Aderian SS, Milane A. Asthma and COPD patients’ perception of appropriate metered-dose inhaler technique. Dose Response. 2020;18(2):1559325820917832. doi:10.1177/1559325820917832

44. Sanaullah T, Khan S, Masoom A, Mandokhail ZK, Sadiqa A, Malik MI. Inhaler use technique in chronic obstructive pulmonary disease patients: errors, practices and barriers. Cureus. 2020;12(9):e10569. doi:10.7759/cureus.10569

45. Harb HS, Ibrahim Laz N, Rabea H, Abdelrahim MEA. Determinants of incorrect inhaler technique in chronic obstructive pulmonary disease patients. Int J Clin Pract. 2021;75(6):e14073. doi:10.1111/ijcp.14073

46. Jang JG, Chung JH, Shin KC, Jin HJ, Lee KH, Ahn JH. Comparative study of inhaler device handling technique and risk factors for critical inhaler errors in Korean COPD patients. Int J Chron Obstruct Pulmon Dis. 2021;16:1051–1059. doi:10.2147/COPD.S303761

47. Nobre Pereira M, Marques T, Areias V, Guerreiro C, Cunha K, Ramos H. Screening of inhalation technique and treatment adherence in asthma, COPD and ACO patients. Pulmonology. 2021;27(4):375–380. doi:10.1016/j.pulmoe.2021.01.006

48. Sulku J, Broms K, Hogman M, et al. Critical inhaler technique errors in Swedish patients with COPD: a cross-sectional study analysing video-recorded demonstrations. NPJ Prim Care Respir Med. 2021;31(1):5. doi:10.1038/s41533-021-00218-y

49. Barnestein-Fonseca P, Cotta-Luque VM, Aguiar-Leiva VP, Leiva-Fernandez J, Martos-Crespo F, Leiva-Fernandez F. The importance of reminders and patient preferences to improve inhaler technique in older adults with COPD. Front Pharmacol. 2023;13:989362. doi:10.3389/fphar.2022.989362

50. Hendrychova T, Svoboda M, Maly J, et al. Self-reported overall adherence and correct inhalation technique discordance in chronic obstructive pulmonary disease population. Front Pharmacol. 2022;13:860270. doi:10.3389/fphar.2022.860270

51. Siler TM, Jain R, Collison K, et al. Correct use and ease-of-use of placebo ELLIPTA dry-powder inhaler in adult patients with chronic obstructive pulmonary disease. PLoS One. 2022;17(8):e0273170. doi:10.1371/journal.pone.0273170

52. Sulku J, Janson C, Melhus H, et al. Changes in critical inhaler technique errors in inhaled COPD treatment - a one-year follow-up study in Sweden. Respir Med. 2022;197:106849. doi:10.1016/j.rmed.2022.106849

53. Brusselle G, Himpe U, Fievez P, et al. Evolving to a single inhaler extrafine LABA/LAMA/ICS - inhalation technique and adherence at the heart of COPD patient care (TRIVOLVE). Respir Med. 2023;218:107368. doi:10.1016/j.rmed.2023.107368

54. Dijk L, Kerkhof M, Driessen M, et al. Does mixing inhaler devices lead to unchecked inhaler technique errors in patients with COPD? Findings from the cross-sectional observational MISMATCH study. BMJ Open Respir Res. 2023;10(1). doi:10.1136/bmjresp-2023-001821

55. Montes Cardona JA, Hincapie Erira DA, Nati-Castillo HA, Sanchez-Vallejo J, Izquierdo-Condoy JS. Characteristics of inhaler technique in COPD patients in a specialized center in Armenia, Colombia: a cross-sectional study. Patient Prefer Adherence. 2023;17:2025–2038. doi:10.2147/PPA.S417375

56. Bosnic-Anticevich S, Bender BG, Shuler MT, Hess M, Kocks JWH. Recognizing and tackling inhaler technique decay in asthma and chronic obstructive pulmonary disesase (COPD) clinical practice. J Allergy Clin Immunol Pract. 2023;11(8):2355–2364e2355. doi:10.1016/j.jaip.2023.04.031

57. Gillissen A, Gessner C, Hechenbichler K, et al. Patient satisfaction and clinical outcomes with budesonide plus formoterol Spiromax for asthma and chronic obstructive pulmonary disease: a real-world, observational trial. Respiration. 2019;97(4):292–301. doi:10.1159/000493860

58. Plaza V, Giner J, Rodrigo GJ, Dolovich MB, Sanchis J. Errors in the use of inhalers by health care professionals: a systematic review. J Allergy Clin Immunol Pract. 2018;6(3):987–995. doi:10.1016/j.jaip.2017.12.032

59. Mannino D, Bogart M, Wu B, et al. Adherence and persistence to once-daily single-inhaler versus multiple-inhaler triple therapy among patients with chronic obstructive pulmonary disease in the USA: a real-world study. Respir Med. 2022;197:106807. doi:10.1016/j.rmed.2022.106807

60. Zhang S, King D, Rosen VM, Ismaila AS. Impact of single combination inhaler versus multiple inhalers to deliver the same medications for patients with asthma or COPD: a systematic literature review. Int J Chron Obstruct Pulmon Dis. 2020;15:417–438. doi:10.2147/COPD.S234823

61. Usmani OS, Hickey AJ, Guranlioglu D, et al. The impact of inhaler device regimen in patients with asthma or COPD. J Allergy Clin Immunol Pract. 2021;9(8):3033–3040e3031. doi:10.1016/j.jaip.2021.04.024

62. Rothnie KJ, Wood RP, Czira A, et al. Outcomes of patients with COPD switching from multiple-inhaler to once-daily single-inhaler triple therapy in a real-world primary care setting in England: a retrospective pre-post cohort study. BMJ Open Respir Res. 2024;11(1). doi:10.1136/bmjresp-2023-001890

63. Dal Negro RW, Povero M. Acceptability and preference of three inhalation devices assessed by the Handling Questionnaire in asthma and COPD patients. Multidiscip Respir Med. 2016;11:7. doi:10.1186/s40248-016-0044-5

64. Navaie M, Dembek C, Cho-Reyes S, Yeh K, Celli BR. Device use errors with soft mist inhalers: a global systematic literature review and meta-analysis. Chron Respir Dis. 2020;17:1479973119901234. doi:10.1177/1479973119901234

65. Gonzalez-Torralba F, Baloira A, Abad A, et al. FIDEPOC: consensus on inspiratory flow and lung deposition as key decision factors in COPD inhaled therapy. Int J Chron Obstruct Pulmon Dis. 2022;17:1005–1015. doi:10.2147/COPD.S360938

66. Dhand R, Dolovich M, Chipps B, Myers TR, Restrepo R, Farrar JR. The role of nebulized therapy in the management of COPD: evidence and recommendations. COPD. 2012;9(1):58–72. doi:10.3109/15412555.2011.630047

67. Talwar D, Ramanathan R, Lopez M, Hegde R, Gogtay J, Goregaonkar G. The emerging role of nebulization for maintenance treatment of chronic obstructive pulmonary disease at home. Lung India. 2021;38(2):168–173. doi:10.4103/lungindia.lungindia_68_20

68. Arora P, Kumar L, Vohra V, et al. Evaluating the technique of using inhalation device in COPD and bronchial asthma patients. Respir Med. 2014;108(7):992–998. doi:10.1016/j.rmed.2014.04.021

69. Sivadasan S, Krishnan A, Dhayalan SV, Aiyalu R. A systematic review on KAP of nebulization therapy at home. J Pharm Technol. 2021;37(5):254–259. doi:10.1177/87551225211031331

70. Foster AA, Stoll J, Daly CJ, Clark CM, Sethi S, Jacobs DM. Patient and social factors related to nebulizer use in COPD patients at the transition of care: a qualitative study. BMC Pulm Med. 2023;23(1):358. doi:10.1186/s12890-023-02651-w

71. Feldman WB, Bloomfield D, Beall RF, Kesselheim AS. Brand-name market exclusivity for nebulizer therapy to treat asthma and COPD. Nat Biotechnol. 2022;40(9):1319–1325. doi:10.1038/s41587-022-01451-7

72. Feldman WB, Tu SS, Alhiary R, Kesselheim AS, Wouters OJ. Manufacturer revenue on inhalers after expiration of primary patents, 2000-2021. JAMA. 2023;329(1):87–89. doi:10.1001/jama.2022.19691

73. Malla G, Bodduluri S, Sthanam V, Sharma G, Bhatt SP. Access to pulmonary rehabilitation among Medicare beneficiaries with chronic obstructive pulmonary disease. Ann Am Thorac Soc. 2023;20(4):516–522. doi:10.1513/AnnalsATS.202204-318OC

74. Wen X, Qiu H, Yu B, et al. Cost-related medication nonadherence in adults with COPD in the United States 2013-2020. BMC Public Health. 2024;24(1):864. doi:10.1186/s12889-024-18333-z

75. Larson T. Economic impact and chronic obstructive pulmonary disease outcomes of a comprehensive inhaler to nebulization therapy protocol implementation in a large multi-state healthcare system. Curr Med Res Opin. 2019;35(10):1805–1817. doi:10.1080/03007995.2019.1628562

76. Sadowski CA, Cor K, Cave A, Banh HL. Administration technique and acceptance of inhaler devices in patients with asthma or COPD. Ann Pharmacother. 2015;49(6):639–648. doi:10.1177/1060028015579097

77. Miravitlles M, Montero-Caballero J, Richard F, et al. A cross-sectional study to assess inhalation device handling and patient satisfaction in COPD. Int J Chron Obstruct Pulmon Dis. 2016;11:407–415. doi:10.2147/COPD.S91118

78. Zervas E, Samitas K, Gaga M. Assessment of satisfaction with different dry powder inhalation devices in Greek patients with COPD and asthma: the ANASA study. Int J Chron Obstruct Pulmon Dis. 2016;11:1845–1855. doi:10.2147/COPD.S113870

79. Ding B, Small M, Scheffel G, Holmgren U. Maintenance inhaler preference, attribute importance, and satisfaction in prescribing physicians and patients with asthma, COPD, or asthma-COPD overlap syndrome consulting for routine care. Int J Chron Obstruct Pulmon Dis. 2018;13:927–936. doi:10.2147/COPD.S154525

80. Contoli M, Rogliani P, Di Marco F, et al. Satisfaction with chronic obstructive pulmonary disease treatment: results from a multicenter, observational study. Ther Adv Respir Dis. 2019;13:1753466619888128. doi:10.1177/1753466619888128

81. Jang JG, Lee KH, Chung JH, et al. Assessment of inhaler satisfaction and determinants of high satisfaction among Korean COPD patients. J Korean Med Sci. 2022;37(46):e327. doi:10.3346/jkms.2022.37.e327

82. Donaire JG, Perez DD, Hernandez C, Cabestre R. Study to evaluate satisfaction with the inhalation device used by patients with asthma or chronic obstructive pulmonary disease and the association with adherence and disease control. J Aerosol Med Pulm Drug Deliv. 2020;33(3):153–160. doi:10.1089/jamp.2019.1541

83. Plaza V, Giner J, Curto E, et al. Determinants and differences in satisfaction with the inhaler among patients with asthma or COPD. J Allergy Clin Immunol Pract. 2020;8(2):645–653. doi:10.1016/j.jaip.2019.09.020

84. Chrystyn H, Small M, Milligan G, Higgins V, Gil EG, Estruch J. Impact of patients‘satisfaction with their inhalers on treatment compliance and health status in COPD. Respir Med. 2014;108(2):358–365. doi:10.1016/j.rmed.2013.09.021

85. Kerwin EM, Donohue JF, Ferguson GT, Ganapathy V, Ozol-Godfrey A, Rajagopalan K. Satisfaction with the use of eFlow closed-system nebulizer in patients with moderate-to-very severe chronic obstructive pulmonary disease: findings from a long-term safety study. J Aerosol Med Pulm Drug Deliv. 2019;32(1):24–33. doi:10.1089/jamp.2018.1477

86. Stephenson JJ, Dembek C, Caldwell-Tarr A, Conto RM, Paullin M, Kerwin EM. Observational real-world study to assess clinical characteristics and device satisfaction in patients with COPD treated with glycopyrrolate/eFlow((R)) CS. Int J Chron Obstruct Pulmon Dis. 2020;15:1713–1727. doi:10.2147/COPD.S248760

87. Dhand R, Mahler DA, Carlin BW, et al. Results of a patient survey regarding COPD knowledge, treatment experiences, and practices with inhalation devices. Respir Care. 2018;63(7):833–839. doi:10.4187/respcare.05715

88. Alsuwaigh R, Cao Y, Puan Y, et al. Nebulizer versus metered dose inhaler with space chamber (MDI spacer) for acute asthma and chronic obstructive pulmonary disease exacerbation: attitudes of patients and healthcare providers in the COVID-19 era. J Asthma. 2023;60(3):600–608. doi:10.1080/02770903.2022.2082307

89. Ram FS, Brocklebank DM, Muers M, Wright J, Jones PW. Pressurised metered-dose inhalers versus all other hand-held inhalers devices to deliver bronchodilators for chronic obstructive pulmonary disease. Cochrane Database Syst Rev. 2002;2002(1):CD002170. doi:10.1002/14651858.CD002170

90. Dolovich MB, Ahrens RC, Hess DR, et al. Device selection and outcomes of aerosol therapy: evidence-based guidelines: American College of Chest Physicians/American College of Asthma, Allergy, and Immunology. Chest. 2005;127(1):335–371. doi:10.1378/chest.127.1.335

91. van Geffen WH, Douma WR, Slebos DJ, Kerstjens HA. Bronchodilators delivered by nebuliser versus pMDI with spacer or DPI for exacerbations of COPD. Cochrane Database Syst Rev. 2016;2016(8):CD011826. doi:10.1002/14651858.CD011826.pub2

92. Wise RA, Acevedo RA, Anzueto AR, et al. Guiding principles for the use of nebulized long-acting beta2-agonists in patients with COPD: an expert panel consensus. Chronic Obstr Pulm Dis. 2016;4(1):7–20. doi:10.15326/jcopdf.4.1.2016.0141

93. Scotet V, L’Hostis C, Ferec C. The changing epidemiology of cystic fibrosis: incidence, survival and impact of the CFTR gene discovery. Genes. 2020;11(6):589. doi:10.3390/genes11060589

94. Yohannes AM, Chen W, Moga AM, Leroi I, Connolly MJ. Cognitive impairment in chronic obstructive pulmonary disease and chronic heart failure: a systematic review and meta-analysis of observational studies. J Am Med Dir Assoc. 2017;18(5):451. doi:10.1016/j.jamda.2017.01.014

95. Henkle BE, Freese RL, Dahlheimer M, Kane C, Hoth KF, Kunisaki KM. Cognitive function and inhaler technique following recovery from exacerbations of COPD. ERJ Open Res. 2023;9(3):00627–2022. doi:10.1183/23120541.00627-2022

96. Baird C, Lovell J, Johnson M, Shiell K, Ibrahim JE. The impact of cognitive impairment on self-management in chronic obstructive pulmonary disease: a systematic review. Respir Med. 2017;129:130–139. doi:10.1016/j.rmed.2017.06.006

97. Kovarik M, Joskova V, Patkova A, Koblizek V, Zadak Z, Hronek M. Hand grip endurance test relates to clinical state and prognosis in COPD patients better than 6-minute walk test distance. Int J Chron Obstruct Pulmon Dis. 2017;12:3429–3435. doi:10.2147/COPD.S144566

98. Rassam P, Pazzianotto-Forti EM, Matsumura U, et al. Impact of cognitive capacity on physical performance in chronic obstructive pulmonary disease patients: a scoping review. Chron Respir Dis. 2023;20:14799731231163874. doi:10.1177/14799731231163874

99. Witt LJ, Spacht WA, Carey KA, et al. Weak handgrip at index admission for acute exacerbation of COPD predicts all-cause 30-day readmission. Front Med Lausanne. 2021;8:611989. doi:10.3389/fmed.2021.611989

100. Gray SL, Williams DM, Pulliam CC, Sirgo MA, Bishop AL, Donohue JF. Characteristics predicting incorrect metered-dose inhaler technique in older subjects. Arch Intern Med. 1996;156(9):984–988. doi:10.1001/archinte.1996.00440090084008

101. Baloira A, Abad A, Fuster A, et al. Lung deposition and inspiratory flow rate in patients with chronic obstructive pulmonary disease using different inhalation devices: a systematic literature review and expert opinion. Int J Chron Obstruct Pulmon Dis. 2021;16:1021–1033. doi:10.2147/COPD.S297980

102. Clark AR, Weers JG, Dhand R. The confusing world of dry powder inhalers: it is all about inspiratory pressures, not inspiratory flow rates. J Aerosol Med Pulm Drug Deliv. 2020;33(1):1–11. doi:10.1089/jamp.2019.1556

103. Ghosh S, Pleasants RA, Ohar JA, Donohue JF, Drummond MB. Prevalence and factors associated with suboptimal peak inspiratory flow rates in COPD. Int J Chron Obstruct Pulmon Dis. 2019;14:585–595. doi:10.2147/COPD.S195438

104. Loh CH, Peters SP, Lovings TM, Ohar JA. Suboptimal inspiratory flow rates are associated with chronic obstructive pulmonary disease and all-cause readmissions. Ann Am Thorac Soc. 2017;14(8):1305–1311. doi:10.1513/AnnalsATS.201611-903OC

105. Mahler DA, Ohar JA, Barnes CN, Moran EJ, Pendyala S, Crater GD. Nebulized versus dry powder long-acting muscarinic antagonist bronchodilators in patients with COPD and suboptimal peak inspiratory flow rate. Chronic Obstr Pulm Dis. 2019;6(4):321–331. doi:10.15326/jcopdf.6.4.2019.0137

106. Araujo AD, Correia-de-Sousa J. COPD: will there be room for nebulisers after the current COVID-19 pandemic? Open Respir Arch. 2020;2(4):265–266. doi:10.1016/j.opresp.2020.08.001

107. Attaway A, Hatipoglu U. Management of patients with COPD during the COVID-19 pandemic. Cleve Clin J Med. 2020. doi:10.3949/ccjm.87a.ccc007

108. Deslee G, Zysman M, Burgel PR, et al. Chronic obstructive pulmonary disease and the COVID-19 pandemic: reciprocal challenges. Respir Med Res. 2020;78:100764. doi:10.1016/j.resmer.2020.100764

109. Upadhya P, Vadala R, A A. Hospital treatment of severe acute exacerbation of chronic obstructive pulmonary disease in COVID-19 situation: back to basics. Monaldi Arch Chest Dis. 2020;90(4). doi:10.4081/monaldi.2020.1424

110. Ari A, Blain K, Soubra S, Hanania NA. Treating COPD patients with inhaled medications in the era of COVID-19 and beyond: options and rationales for patients at home. Int J Chron Obstruct Pulmon Dis. 2021;16:2687–2695. doi:10.2147/COPD.S332021

111. Farrugia Y, Spiteri Meilak BP, Grech N, et al. The impact of COVID-19 on hospitalised COPD exacerbations in Malta. Pulm Med. 2021;2021:5533123. doi:10.1155/2021/5533123

112. Biney IN, Ari A, Barjaktarevic IZ, et al. Guidance on mitigating the risk of transmitting respiratory infections during nebulization by the COPD Foundation Nebulizer Consortium. Chest. 2024;165(3):653–668. doi:10.1016/j.chest.2023.11.013

113. Peche R, Attar-Zadeh D, Scullion J, Kocks J. Matching the inhaler to the patient in COPD. J Clin Med. 2021;10(23). doi:10.3390/jcm10235683

114. Wongsurakiat P, Rattanawongpaibul A, Limsukon A, et al. Expert panel consensus recommendations on the utilization of nebulized budesonide for managing asthma and COPD in both stable and exacerbation stages in Thailand. J Asthma. 2024;1–16 doi:10.1080/02770903.2024.2334897.

115. Terry PD, Dhand R. Nebulizers. Inhaled Delivery Systems for the Treatment of Asthma and COPD. 1st ed. CRC Press; 2023.

116. Edge R, Butcher R. CADTH rapid response report: summary with critical appraisal. Vibrating Mesh Nebulizers for Patients with Respiratory Conditions: Clinical Effectiveness, Cost-Effectiveness, and Guidelines. Ottawa (ON): Canadian Agency for Drugs and Technology in Health (CADTH); 2019.

117. Feng Z, Han Z, Wang Y, Guo H, Liu J. Comparison of the application of vibrating mesh nebulizer and jet nebulizer in chronic obstructive pulmonary disease: a systematic review and meta-analysis. Int J Chron Obstruct Pulmon Dis. 2024;19:829–839. doi:10.2147/COPD.S452191

118. Lin HL, Chen CS, Fink JB, et al. In vitro evaluation of a vibrating-mesh nebulizer repeatedly use over 28 days. Pharmaceutics. 2020;12(10):971. doi:10.3390/pharmaceutics12100971

119. Brennan M, McDonnell MJ, Harrison MJ, et al. Antimicrobial therapies for prevention of recurrent acute exacerbations of COPD (AECOPD): beyond the guidelines. Respir Res. 2022;23(1):58. doi:10.1186/s12931-022-01947-5

120. Han Y, Hua J, He B, Zhang J. Inhaled antibiotics and airway bacterial decolonization for patients with chronic obstructive pulmonary disease: the rationale and future. J Transl Int Med. 2022;10(3):181–184. doi:10.2478/jtim-2022-0005

121. Lal C, Khan A. Emerging treatments for COPD: evidence to date on revefenacin. COPD. 2020;17(1):112–119. doi:10.1080/15412555.2019.1702010

122. Nikander K, Turpeinen M, Wollmer P. The conventional ultrasonic nebulizer proved inefficient in nebulizing a suspension. J Aerosol Med. 1999;12(2):47–53. doi:10.1089/jam.1999.12.47

123. Cazzola M, Page C, Calzetta L, Singh D, Rogliani P, Matera MG. What role will ensifentrine play in the future treatment of chronic obstructive pulmonary disease patients? Implications from recent clinical trials. Immunotherapy. 2023;15(18):1511–1519. doi:10.2217/imt-2023-0136

124. Anzueto A, Barjaktarevic IZ, Siler TM, et al. Ensifentrine, a novel phosphodiesterase 3 and 4 inhibitor for the treatment of chronic obstructive pulmonary disease: randomized, double-blind, placebo-controlled, multicenter Phase III trials (the ENHANCE Trials). Am J Respir Crit Care Med. 2023;208(4):406–416. doi:10.1164/rccm.202306-0944OC

125. Cazzola M, Ora J, Calzetta L, Rogliani P, Matera MG. The future of inhalation therapy in chronic obstructive pulmonary disease. Curr Res Pharmacol Drug Discov. 2022;3:100092. doi:10.1016/j.crphar.2022.100092

126. Gomes F, Cheng SL. Pathophysiology, therapeutic targets, and future therapeutic alternatives in COPD: focus on the importance of the cholinergic system. Biomolecules. 2023;13(3):476. doi:10.3390/biom13030476

127. Parrott TD, Wallace MD, Niehoff KM, et al. Pharmacist review of chronic inhaler therapy appropriateness for hospitalized patients with COPD or asthma. J Am Coll Clin Pharm. 2023;6(12):1304–1312. doi:10.1002/jac5.1862

128. Sanders MJ. Guiding inspiratory flow: development of the In-Check DIAL G16, a tool for improving inhaler technique. Pulm Med. 2017;2017:1495867. doi:10.1155/2017/1495867

129. Alotaibi MM, Hughes L, Ford WR. Assessing inhaler techniques of asthma patients using aerosol inhalation monitors (AIM): a cross-sectional study. Healthcare. 2023;11(8). doi:10.3390/healthcare11081125

130. Alhaddad B, Smith FJ, Robertson T, Watman G, Taylor KM. Patients’ practices and experiences of using nebuliser therapy in the management of COPD at home. BMJ Open Respir Res. 2015;2(1):e000076. doi:10.1136/bmjresp-2014-000076

131. Braman SS, Carlin BW, Hanania NA, et al. Results of a pulmonologist survey regarding knowledge and practices with inhalation devices for COPD. Respir Care. 2018;63(7):840–848. doi:10.4187/respcare.05717

132. Alhaddad B, Taylor KM, Robertson T, Watman G, Smith FJ. Assistance of family carers for patients with COPD using nebulisers at home: a qualitative study. Eur J Hosp Pharm. 2016;23(3):156–160. doi:10.1136/ejhpharm-2015-000735

Creative Commons License © 2024 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, 3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.